INDUSTRIAL RFID TAGS

Rugged RFID Tags for Harsh Industrial Environments

Protective UHF RFID tag platforms for metal assets where enclosure, mounting retention, weather exposure and other service conditions must be evaluated together.

Define the failure risk first — “rugged” is not a single specification.

ExposureIndoor / outdoor / moisture
Mechanical loadImpact / vibration / handling
MountingBolt / rivet / adhesive / epoxy
Asset surfaceMetal / non-metal / geometry
Read taskDistance / angle / speed

A protective housing is only the starting point. Define the actual exposure and mechanical load, then validate both retention and RFID performance on the real asset.

1
Ruggedness is a service-condition requirement

This directory is for protective RFID tag platforms selected against defined environmental and mechanical risks—not every product historically described as hard, durable or industrial.

2
Metal is a substrate; ruggedness is a survival requirement

Use On-Metal RFID Tags when RF performance on metal is the main need. Use this directory when enclosure, mounting and service exposure create an additional survival requirement.

SIX PRACTICAL SELECTION PATHS

Choose by installation and operating risk

Start with the way the tag can fail in service. Then confirm form factor, mounting, substrate, frequency region and the installed read zone.

LOW-PROFILE METAL ASSETS

Thin protective tags for limited clearance

For racks, tools, fixtures and reusable metal assets where a protective housing must fit a shallow mounting envelope.

MECHANICAL FASTENING

Bolt- or rivet-mounted industrial assets

For metal containers, equipment and RTIs where through-hole mechanical fixation is preferred over an adhesive-only installation.

BONDED INSTALLATION

Adhesive or epoxy mounting without drilling

For metal assets where the installation process favors a bonded tag and the surface can be prepared and validated before deployment.

RUGGED + HIGH TEMPERATURE

Protected tags for thermal exposure

For metal assets exposed to elevated temperature where enclosure protection, mounting and thermal cycles must be evaluated together.

THREADED METAL INSTALLATION

Compact steel-mounted tag platforms

For tools and industrial assets where a threaded or welded stainless-steel installation is preferred and heat exposure is defined.

EXTREME HEAT / HOT-STATE ID

Direct identification in extreme industrial heat

For hot metal assets where normal identification during heat exposure—not only survival after cooling—is the decisive requirement.

CORE PRODUCT RANGE

Core Rugged RFID Tags

SPECIALIST OPTIONS FOR HARSH ENVIRONMENTS

Add temperature only when it is a real operating constraint

These products retain the High-Temperature RFID Tags directory as their primary category. They appear here only when elevated temperature is a separate, defined operating constraint in addition to mounting and environmental exposure.

SPECIALIST OPTION 01

Rugged High-Temperature RFID Tags

For industrial assets where temperature, mounting and service exposure must be assessed together. The curated module covers enclosed long-range platforms, a threaded stainless-steel platform and an extreme-heat hot-state platform.

Use this module when

The customer can define peak temperature, dwell time, thermal cycles, asset surface, mounting and whether reading is required while hot or after cooling.

Do not select on this basis when

“High temperature” is undefined, or an exposure rating is being treated as proof of normal read/write performance at the maximum temperature.

View the High-Temperature RFID Tags directory →
EVIDENCE GATE

Translate “rugged” into testable conditions

Define the actual service environment before choosing a tag or publishing a claim.

  • Indoor, outdoor, rain, wash-down or immersion exposure
  • Shock, vibration, abrasion and handling frequency
  • Chemicals, oils, cleaning agents, UV and contamination
  • Peak temperature, dwell time and thermal cycles
  • Mounting force, retention method and available clearance
  • Required read zone, reader, antenna and frequency region
DEPLOYMENT VALIDATION

Test both survival and RFID performance

Housing design and production experience are not substitutes for project-specific evidence. Use representative assets and the intended reader setup to validate mounting retention, service exposure and the required read zone before volume deployment.

INDUSTRIAL APPLICATIONS

Typical rugged RFID applications

Outdoor Equipment & Metal Infrastructure
Returnable Containers, Pallets & RTIs
Tools, Fixtures & MRO Assets
Racks, Trolleys & Production Assets
Industrial Work-in-Process
APPLICATION-SPECIFIC ENGINEERING

When a standard rugged tag does not fit

Crepak can adapt a qualified platform through controlled changes to housing, mounting, chip, frequency, marking or encoding. A platform derivative should be validated before a full NPI is considered.

EnvironmentPlatformConfigurationDerivativeValidationProduction
FAQ

Engineering questions before selection

What makes an RFID tag rugged?

Ruggedness should describe a protective construction matched to a defined service condition. A hard enclosure, industrial name or long read range alone is not enough.

How should the IP67 specification be used?

Saber 50 and Saber 60 are supplied as IP67 products based on their housing design and production experience. If a project requires third-party certification or a customer-defined ingress test, include that requirement in the RFQ.

Are the Saber core products designed for metal assets?

Yes. Saber 50 and Saber 60 are positioned as rugged on-metal UHF RFID tags. The installed range must still be validated on the actual metal geometry with the intended mounting and reader setup.

What is the difference between Saber 50 and Saber 60?

Saber 50 is the lower-profile platform for limited clearance and supports screw or bolt, adhesive and epoxy installation. Saber 60 is the mechanically fastened platform with 4.0 mm mounting holes at 76.5 mm spacing, recommended for bolt or rivet installation while also supporting adhesive or epoxy.

Are impact, vibration, UV and chemical limits formally tested?

No blanket tested limits are currently published for the Saber core products. Define the actual load and exposure in the RFQ, then validate representative samples when these conditions are part of the acceptance criteria.

Which regional frequency versions are available?

Both Saber 50 and Saber 60 are available in ETSI and FCC versions. Confirm the deployment region before samples or production are prepared.

Is the longest published read range the best selection criterion?

No. The installed read zone depends on asset geometry, reader, antenna, orientation, mounting and surroundings. Choose for the complete service condition and validate the required acceptance distance.

Can a high-temperature rugged tag be read at its maximum exposure temperature?

Do not assume so. Most maximum temperature values describe exposure or survival. Hot-state operation must be confirmed separately; Uru 40 is the specialist platform on this page for defined hot-state identification.

Why are there only two products in the core Rugged directory?

The active core directory is deliberately evidence-gated. Products are not included merely because they were historically called durable, industrial or rugged. Specialist high-temperature products keep their own primary directory.

ENGINEERING RFQ

Send us the asset, environment and read requirement

Describe the conditions that can cause tag failure. Crepak can then narrow the choice to a standard platform, specialist product or controlled derivative.

Asset photo or drawing
Surface material and geometry
Available mounting space
Outdoor / water / chemical exposure
Shock / vibration / temperature
Reader, region and required distance
Request Tag Recommendation
This website uses cookies to improve your experience. By using this website you agree to our Data Protection Policy.
Read more