SPECIALTY INDUSTRIAL RFID

High Temperature RFID Tags

Industrial RFID tags for tools, metal assets, WIP and production processes exposed to elevated temperatures. Select by temperature profile, mounting, construction and whether RFID reading is required during or after heat exposure.

Start with the process — not just the maximum temperature.

Maximum temperature180°C / 225°C / 250°C / 350°C+
Heat conditionExposure or operation
MountingAdhesive / screw / rivet / weld
Asset surfaceMetal / non-metal
Read conditionAfter cooling / during heat

Except for Uru 40, high-temperature ratings refer primarily to heat exposure. Reading after cooling is recommended because read range can decrease while the tag is hot.

1
Exposure / survival

HT10, Tumbler and standard Uru models are primarily selected to survive high-temperature exposure and are normally read after cooling.

2
Hot-state operation

Uru 40 is the special SAW solution for applications that require RFID operation while the asset is still hot.

SIX PRACTICAL SELECTION PATHS

Choose the product family first

Each path gives one recommended starting product. The complete product range below shows all available models once you know which family fits your application.

UP TO 180°C EXPOSURE

Flexible high-temperature label

For non-metal assets where a thin, flexible and economical RFID label is preferred.

UP TO 250°C EXPOSURE

Compact ceramic tags

For tools, fixtures and space-constrained metal assets requiring a very small on-metal tag.

225–250°C EXPOSURE

Rugged long-range tags

For industrial metal assets requiring stronger packaging, mechanical mounting and longer read range.

UP TO 250°C EXPOSURE

Threaded stainless-steel tags

For assets where a compact threaded metal tag is more reliable than adhesive mounting.

UP TO 250°C EXPOSURE

Flat heavy-duty metal tag

For heavy industrial equipment requiring a robust plate-style stainless-steel RFID tag.

UP TO 350°C OPERATION

Ultra-high-temperature RFID

For extreme-temperature processes requiring RFID operation while the asset is still hot.

APPLICATION VALIDATION

Validate against the real thermal process

Maximum-temperature ratings alone do not guarantee performance in a specific application.

  • Peak temperature and exposure duration
  • Number and frequency of thermal cycles
  • RF performance before and after exposure
  • Mounting material and fixation method
  • Chemicals, wash-down, shock and vibration
  • Application-specific failure risks
EVALUATE BEFORE SCALE

Use an application-matched evaluation pack

Validate representative tags against the real thermal cycle, mounting surface and read environment before volume deployment. The recommended sample set depends on the application and available product configurations.

INDUSTRIAL APPLICATIONS

Typical high-temperature RFID applications

Automotive Paint Shop / WIP
Industrial Tools & Fixtures
Injection Molds
Metal Processing
Industrial Ovens & Heat Processes
APPLICATION-SPECIFIC ENGINEERING

When the standard range is not enough

If none of the standard products fits because of OEM integration, unusual mechanical constraints, special materials or validation requirements, Crepak can adapt an existing platform or develop a platform derivative before considering a full NPI.

PlatformConfigurationDerivativeNPIValidationProduction
FAQ

Engineering questions before selection

Does a 250°C rating mean the RFID tag can be read and written at 250°C?

No. For Crepak's standard high-temperature UHF products, the maximum value primarily describes high-temperature exposure/survival. Reading after cooling is recommended, and hot-state read range can be shorter. High-temperature writing should not be assumed.

Which product should I consider for continuous operation at extreme temperature?

Uru 40 is the special high-temperature operating solution in this portfolio. It uses SAW technology, a fixed read-only ID and a compatible SAW reader.

Can these tags be mounted directly on metal?

Most Tumbler and Uru products are designed for metal applications. Energon HT10 is intended for non-metal assets and is not designed for direct metal mounting.

Do you publish a fixed 250°C exposure duration or cycle count?

Not as a universal value. Exposure duration and thermal-cycle life depend on the exact product, mounting and process. Application validation is recommended for demanding thermal profiles.

APPLICATION-MATCHED EVALUATION PACK

Request a High-Temperature RFID Evaluation Pack

Share the thermal process, asset and read conditions. Crepak will recommend representative samples for validation before volume deployment. Availability, pricing and included models depend on the project. RAIN UHF evaluation packs and Uru 40 SAW evaluations are scoped separately: Uru 40 requires matched Crepak SAW reader hardware and is not included in a standard UHF sample set.

Peak temperature
Exposure duration / cycle frequency
Asset material
Available mounting space
Required read range
Mounting method
Reader / frequency region
Estimated quantity / annual volume
Request Evaluation Pack
This website uses cookies to improve your experience. By using this website you agree to our Data Protection Policy.
Read more